Equations (12-1) and (12-2) deal with a gas. Ive posted a few pictures at: Any help much appreciated Richard.A fire truck moves water from a river through a hose (0.1-m diameter roughness of 4.57 x m) to a height 30. I have no manual, dont know its power output, and dont even know who made it Beneath the gas power dial, on a yellowed old aluminium plate, is STREAMLINE in red type. By libaswhicost1979 Follow Public. Sirocco Streamline 2 Gas Fire Manual.BimmerFest BMW Forum Since 2001. AUX DIY BMW Business CD RDS BP3850 - Duration: 2:42 BMW Reverse. Sirocco Streamline 2 Gas Fire Manual Shipping Manifest Templates Cara Download Tanpa Kuota 3 Android Motorola Radius M110 Manual Treadmill Dbs Walk And Follow Fs2004 Free Download New Edition Heartbreak Zippyshare Terra Mobile 1510 Treiber Download Surat Alimron Ayat 159 Mp3 Namma Ooru Nayagan Ramraj Mp3 Download Blood Pressures The.
Sirocco Streamline 2 Gas Fire Install This ApplianceRead all the instructions before continuing to unpack or install this appliance. OPENING THE APPLIANCE Stand the carton the right way up, open the box from the top. Sirocco Streamline 2 Gas Fire Manuals Lib Radeon 6470m Kext Installer Breathe Carolina Album Rar Download Perang Kerajaan 320 Diablo 3 Pc Iso Torrents Downloads Download Kurdish Fonts Zanest Free Download Commentary For Fifa 12 Pc Game Antenna 20 Dbi Wifi Caseras Mess System Bios Roms For Mameox Roms The appliance is designed to fit most types of fireplaces with a natural draught flue as listed in the Installation Requirements. INSTALLATION INSTRUCTIONS These Notes Must Be Read Before Installation This appliance is an Inset Live Fuel Effect appliance that provides radiant or combined radiant and convected heat it cannot and should not be used as the main heating source within a property. Sirocco Streamline 3 Gas fires Model Options Apex, Blenheim, Pinnacle Plus.Daria Gps Voice Download here. Also for: 18''.View and Download Sirocco Streamline 3 installation and user instructions manual online. 16'' indoor fireplace pdf manual download. DECORATIVE FUEL EFFECT APPLIANCE. Section 3: APPLIANCE INFORMATION Streamline 16' Tray 18' Tray Gas Group G20 Natural Gas CAT I2H G20 Natural Gas CAT I2H Inlet Pressure 20 mbar 20 mbar Max Input (gross) Min Input (gross) Setting Pressure 20 mbar 20 mbar Gas Inlet connection 8mm Compression 8mm Compression Overall Height. An extractor fan must not be fitted in the same room or space as the appliance as this can affect the safety of the appliance. Section 2: INSTALLATION REQUIREMENT This appliance MUST NOT be installed into a bathroom or shower room, or where steam may be present. It is the LAW that all gas appliances and fittings are installed by a competent person such as a Gas Safe Registered fitter and in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards for Installation, Codes of Practice and in accordance with the manufacturers’. Section 1: IMPORTANT NOTES This fire is decorative Fuel Effect Gas Fire providing radiant warmth.It is designed to operate on Natural Gas or LPG. INSTRUCTIONS CONTENT Section Contents Page No Important Notes Installation requirements Appliance Information Ventilation Site Requirements Pre-Fabricated Flue box Debris Space Installation of appliance 10-11 Preparing the Opening 11/12 Fitting the Burner Tray 12/14 Fuel Bed 15-18 Commissioning the Appliance Operating the Appliance Manual Control 10.1 Operating the Appliance Remote Control 19-20. Protect the decorative hearth whilst aligning the tray within the opening part of the packaging or a dust sheet can be used. If problems are found DO NOT fit the fire until corrective measures have been completed. SECTION 7.1: PREPARING THE OPENING Before installing the fire, check the flue for correct operation using a smoke pellet, all of the smoke should be drawn up the flue and exit correctly from the terminal. CLAY/CEMENT LINES OR BLOCK FLUE WHICH IS NEW, UNUSED, OR PREVIOUSLY ONLY USED WITH A GAS FIRE. Now Place another row of 4 as shown below, again coals may be rotated slightly within their positions to give a good visual effect.Note: The coals must not be crammed together, or inserted into the holes in the matrix, a well laid out, generously spaced coal layout will give the best results. Now Place the next rows as shown below, coals may be rotated slightly within their positions to give a good visual effect. Now place 4 coals across the back and four coals across the front these may vary in size and shape also you can over hang the cast edges of the tray to help fill in the outer areas of the opening, leave a gap close to the pilot to help with cross lighting. Remote Control options will need the 3 x AA batteries (Ever Ready Energisers alkaline battery maybe used or Lithium type batteries can be used) to be placed within the valve compartment and 2 x AA batteries for the hand set.Note: Fitting the batteries incorrectly could lead to damaging your control box. Fit the two securing screws through the front plate ensuring that the plate is in front of the front edge of the base plate, if using a Hotbox or Convector box then ensure the base plate is behind the plate on the box. If the fire is the manual control system, you can now place the burner tray into the base plate making sure that the back lugs locate properly into the back of the plate. SECTION 12: FLUE SPILLAGE MONITORING SYSTEM Remote controlled fires are fitted with a flue spillage safety device (ODS). Section 9: COMMISSIONING THE APPLIANCE Turn on and test the gas supply up to the fire for any leaks, in accordance with current Approved Codes of Practice (ACOPs) Section 10: OPERATING THE APPLIANCE (See Section 18 Users Instruction) SECTION 11: SETTING PRESSURE Remove the pressure test point sealing screw from the isolation elbow and attach a suitable pressure gauge. The fire front/fret supplied with the appliance, we strongly recommend you use one supplied by Sirocco fires as these products will have been tested with the appliance, although other fire front/frets will be compatible. Ensure that the fire is fully cold before attempting service. SECTION 15: SERVICING Isolate the fire from the gas supply. After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the informed for the need of regular servicing. Show the customer how to light and operate the fire. SECTION 14: BRIEFING THE CUSTOMER All instructions must be handed to the user for safekeeping. New hdd regenerator 2011 serial number crack full download 2016 free and softwareBe careful not to create dust from the coals.Where necessary replace damaged components with genuine spares. Gently clean in the open air using a dry paint brush. Remove the ceramic components. SECTION 16: CLEANING THE COALS Remove the fire front/fret casting and place to one side. Lay out the dust sheet and tools required. Check all isolators are adequately sized and fully open. If pressure is low, remove any restriction in pipe work or valve. Pilot flame shrinks when fire is on high?Poor gas flow to fire, check pressure with fire on high. OPERATING THE APPLIANCE (Remote control) IMPORTANT USER INFORMATION – AFTER INSTALLATION BY THE ENGINEER, READ THIS BEFORE ATTEMPTING TO OPERATE THE FIRE Insert the batteries in the TESC Control and handset as show inside the battery cover and slide isolation switch to the I position of gas control Hold the handset and the green unlock light will illuminate allowing the buttons to work. To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. The main burner should light after a few seconds, to decrease the setting to LOW, turn the control knob clockwise to the low setting. The requirements of other appliances operating in the same space or room, and the results of a spillage test must be taken into consideration when assessing ventilation requirements, this will have been carried out by your Gas Safe registered installer. A combustible shelf may be fixed to the wall above the fire, providing that it complies with the dimensions given in section 3 site requirements.No purpose provided ventilation is normally required for this appliance. After fitting the batteries and replacing the cover the fire can now operate.
0 Comments
Leave a Reply. |
AuthorHolly ArchivesCategories |